Single handle moen bath fixture only lets out hot water

Posted by hansshop13 on Jan 23, 2009

Research, Knowledge and Information :


How to Change the Hot & Cold Water on a Single-Handle Faucet ...


... while the knob to the left controls hot water. With a single-handle faucet, both hot ... Hot Water Is Not Working With the Moen Single ... Hot Water in the Tub Only?
Read More At : homeguides.sfgate.com...

Moen L2352 Chateau Single Handle PosiTemp Shower ... - amazon.com


Moen L2352 Chateau Single Handle PosiTemp Shower Trim without Valve, Chrome - Single Handle Shower Only Faucets ... 5.0 out of 5 stars Hot showers again!

Replacing Moen Cartridges


This is the basic Moen cartridge used for single-handle ... It does keep you from turning on blistering hot water all ... and it will only pull it out about 1/4 ...
Read More At : pages.cs.wisc.edu...

MOEN 90-Degree Single-Handle 1-Spray ... - The Home Depot


Visit The Home Depot to buy MOEN ... the single-handle faucet lets you adjust water ... It will be at that same warm temperature next time you pull out the handle.
Read More At : www.homedepot.com...

Why does the water temperature fluctuate on this single ...


Why does the water temperature fluctuate on this single handle ... the water out of showerhead gets warm or hot. ... is only seen in one bath (with single handle), ...
Read More At : diy.stackexchange.com...

Moen S6705 90-Degree One-Handle Low-Arc Open Waterway ...


Moen S6705 90-Degree One-Handle Low-Arc Open Waterway Bathroom Faucet with ... Single lever handle for easy water ... 5.0 out of 5 stars FANTASTIC MOEN MODERN ...

Voss Single-Handle 1-Spray Moentrol Tub and Shower Faucet ...


Visit The Home Depot to buy Moen Voss Moentrol Tub ... the single-handle faucet lets you adjust water volume and ... was able to get hot water, but only ...
Read More At : www.homedepot.com...

TUB AND SHOWER VALVES - Moen


Before turning water on during either rough-in or trim-out, ... to be used for a shower only or a tub only, ... to the full hot position (handle pointing to the ...
Read More At : www.moen.com...

Suggested Questions And Answer :


Shower head leaks water when water is turned on


Take out the cartridge from the fixture and make sure it has all of the "O" rings and stoppers. look at the instruction again, make sue you are installing it the right side up. if all that, the shower still leak, then you need to talk to the place you brought the fixture, it may have a defective cartridge.
Read More At : & Posi-Temp Single Handle Shower Or Tub Valve...

Moen single handle valve tub/shower


The Moen Posi-Temp Valve is a pressure balanced valve and when not used for long periods of time they can stick causing only cold or hot water to pass through the valve. A New Posi-temp cartridges can be purchased at most plumbing supply houses or big box outlets such as Lowes or Home Depot. As long as you had cold water before, a new cartridge will solve the problem. In the future it would be wise to occassionally operate the valve at least a couple of times a month in order to keep the pressure assembly from becoming lodged in position. Just follow the instructions included with the new cartridge on the proper removal of the old cartridge and the installation of the new cartridge. a little silicone grease inside of the valve before installing the new cartridge will also help. Be sure that there is no particles of the old cartridge left in the valve. sanray
Read More At : & Posi-Temp Single Handle Shower Or Tub Valve...

Temp control doesn't allow water to get hot enough


Remove the handle and there should be a white plastic deal behind the handle that you can remove it's a temperature limit setter so people dont burn themselves remove it and you will get the full hot water
Read More At : & Posi-Temp Single Handle Shower Or Tub Valve...

MOEN POSI-TEMP GOES FROM HOT TO COOL AFTER 30 SECONDS OR SO


Wow A Mystery Faucet!!! SOUNDS LIKE THE WATER LINES FEEDING THE FAUCET MAY BE SWITCHED. CHECK TO MAKE SURE THE COLD FEED GOES TO THE COLD SIDE AND THE SAME FOR THE HOT. SOMETIMES MISTAKES ARE MADE WHEN INSTALLING THE FAUCET. MAKE SURE THEY ARE CONNECTED THE SAME AS THE 2 THAT ARE WORKING. IF YOU HAVE THE TIME AND PATIENCE, YOU CAN TAKE A WORKING FAUCET AND INSTALL IT IN PLACE OF THE (mystery faucet) AND SEE IF YOU HAVE THE SAME RESULTS. IF YOU GET HOT WATER IN THE TEMPORARY FAUCET, THEN YOU HAVE A DEFECTIVE FAUCET. THESE ARE A FEW TROUBLE SHOOTING TIPS I HOPE THAT MAY HELP YOU.....JOE
Read More At : & Posi-Temp Single Handle Shower Or Tub Valve...

Moen posi-temp for shower pressure


There is a little "o" ring in the shower inlet that is designed to collapse as the pressure increases, limiting flow. You can safely remove this and then have un restricted flow.
Read More At : & Posi-Temp Single Handle Shower Or Tub Valve...

I recently had a new Moen Posi Temp shower valve installed. I'm having an intermittent problem now. At various faucet handle positions, the valve will start sputtering and vibrating. The only way to stop it is to move the handle to another position to change the temperature and then move it back to the original position. - I opened up the shower wall from behind and strapped all the pipes down securely and the problem still exists. With the valve exposed I heard a harsh ticking sound in the valve as the water was sputtering. Can someone please help me? It would be much appreciated.


This problem is in the head of the valve itself. These faucets are complex systems and I have seen many improperly installed. When you pull the cover off (it has an O-ring to create enough friction to keep it in place) you will see a ring with teeth and possibly molded to fit inside the cavity in one of two or four positions. Additionally there are two tiny cups that go behind the head of the shower valve to prevent sputtering . The water must be turned off and lines opened before this is even opened. It sounds to me like one of those little plastic cups is misaligned, possibly leaving just enough space for water under pressure to escape past the wall of the cup, which creates the "sputtering". Only professionals should attempt to install these, and I have even come behind pros that did not understand how they had to be installed. My recommendation is to call back the installer, have him pull it all out, replace that damaged cup and put it back together. You should watch him do it, so that you see what was wrong in the installation. Properly installed there is no way this kind of thing happens. Dan
Read More At : & Posi-Temp Single Handle Shower Or Tub Valve...

Moen Shower Valve Model L82839 installed: Water comes out of shower head when running bath. Thanks.


Only two possibilities here the diverter tub spout is not open all the way to let water to the tub only or the shower valve is installed up-side-down. http://www.moen.com/shared/pdf/l82691pt.pdf
Read More At : & Posi-Temp Single Handle Shower Or Tub Valve...

No water flow


Did this unit come with water stops built into the faucet body? Some of the newer faucets have stops built in and they need to be turned on. Also if you aren't going to plumb the hot in, you will need to cap it off but it should run without it unless it has some sort of balance in it. I don't think so though.
Read More At : & Posi-Temp Single Handle Shower Or Tub Valve...

We have a home that is 3 years old. We never used the 3rd bathroom shower until today. We have a Moen single knobe shower/bath valve. To get water from the faucet you pull the knob out. To adjust the water temp - Left for hot and right for cold. When rotated to the left for hot the water shuts off. When rotated to the right we get only cold water. Could the valve be installed wrong or could the cartridge be installed wrong? Kevin


Remove handle to gain acess to the temperature limit stop. Remove handle and pull out handle adapter kit and next there is a dail that can be adjusted to control the water to balance the temp. It could have been installed wrong, pay attention to where it is now and pull it back to it disengages out of the stem and move it counter clockwise a little and reinstall. Put handle on and test water for correct movement. Go to link below for a part's diagram if needed. TO ORDER PARTS CALL: 1-800-465-6130 www.moen.com
Read More At : & Posi-Temp Single Handle Shower Or Tub Valve...

Moen posi-temp valve with little pressure


I have the same problem. Anyone know how to fix this?
Read More At : & Posi-Temp Single Handle Shower Or Tub Valve...

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.
next Question || Previos Question
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || diydecoridea.com || Terms of Use || Contact || Privacy Policy
Load time: 0.1312 seconds