Heater unit kicks out GFI

COLEMAN hotub california cooperage pump unit runs fine on high & low circulation soon as heater is turned on runs for a minute approx.and kicks out GFI

Research, Knowledge and Information :


My hot tub keeps tripping the gfi but only when the heat is ...


How JustAnswer Works: Ask ... Heating element is the same rating as the one I took out. Gfi unit is only 2 month ... It's when I kick it up on high flow with the ...
Read More At : www.justanswer.com...

Troubleshooting a tripping hot tub GFCI breaker - Hot Tub ...


Troubleshooting a GFCI breaker that ... For parts like the heater that don't plug into ... Use the process of elimination to find out what part is causing the ...
Read More At : www.hottubessentials.com...

GFCI pops when RV plugged in - DSLReports Home


Forum discussion: I plug my RV into a GFI protected 20A circuit, and when I turn on either the A/C or Water heater breaker, the GFI pops, even though the A/C and ...
Read More At : www.dslreports.com...

RV.Net Open Roads Forum: GFI at house trips when camper is ...


... GFI at house trips when camper is ... the water heater before we headed out. The unit is ... short and reasn GFI kicks.Its also possible the element ...
Read More At : www.rv.net...

Refrigerator trips GFCI - Electrical - FMCA Motorhome Forums


Refrigerator trips GFCI ... trip the GFI." I would agree if the heating element is defective by leaking current to ground. But it is a sealed unit like that in ...
Read More At : community.fmca.com...

GFCI trips on my spa - SpaCare


GFCI trips on my spa Spacare.com ... Unplug heater from control box or remove wires ... you helped me figure out what part I needed for my hot tub and I ...
Read More At : spacare.com...

What's Causing a Water Heater to Trip a Circuit Breaker : Hot ...


Feb 01, 2013 · What's Causing a Water Heater to Trip a Circuit Breaker : Hot Water Heaters ... Find out what's causing a water heater to trip a circuit breaker ...

Problems With an Electric Hot Water Heater That Trips a ...


Problems With an Electric Hot Water Heater That Trips a Breaker. ... a problem with the unit's thermostat or a problem with the breaker.
Read More At : homeguides.sfgate.com...

Suggested Questions And Answer :


Heater unit kicks out GFI


Most require a seperate circuit for the heater. depending on HP on the circulation pump and wattage on heater.
Read More At : Home...

I installed an inline jacuzzi heater DQ75000 to an existing tub. It is plugged into it's own GFI line which works. The light that indicates it's heating doesn't come on nor does it seem to be producing any heat. I switched it out with another unit but same result.


Hi,Two things to check...is there enough flow to trip the flow sensor in the heater...the heater will only work when there is flow sensed going through the line...it needs to be in the line diredtly off of the pump before any tee's...Also and this may sound stupid, but stranger things have happened...The heaters are directional and they need to be installed with the flow going the correct direction... have you tried taking it out and reversing it??? The flow may be going the wrong way...heatman101
Read More At : RapidHeat In-Line Heater U395000 [ Bathtubs and Whirlpools,...

Tub heater kicking out


Sounds like a part is bad on the control pack. Whatever gets 'jiggled' when you slam the door down is most likely the bad part.
Read More At : Home...

Jacuzzi Hot Water Heating Capacity


Depending on how you heat the hot water, whether gas or electric, is a missing detail in your problem, but if it is electric then your problem is the size, being only 40 gal, and needing probably about that to fill the tub, will always lead to your current position. If the hot water heater is gas, the chances of it keeping up are slightly better, but again things like the temperature of the water leaving the tank, any mixing valves, etc. will effect the water temp at your tub.  Before raising any temps, make sure you follow local code, as not to scald yourself or others.
Read More At : Home...

The heater is set at 32 degrees but only blows cold air the water bottle is at the right level and the fan runs


Sounds as if your Thermostat is faulty and remaining in the closed position, pop it out, boil a kettle of water drop it into the hot water and check if it is opening. If it does open then your problem most likely is a dirty heating system and it needs to be flushed.
Read More At : 500 core. heater. . a/c and heater unit core. heater...

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.
next Question || Previos Question
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || diydecoridea.com || Terms of Use || Contact || Privacy Policy
Load time: 0.0643 seconds